DTH Drill Pipe

Tubería de perforación DTH de 76 mm, API 2-3/8 REG

Model:76 mm / API 2-3/8 REG

Selected configuration:1000 mm

Selected reference:PFM-DTH76-238-1000

76 mm DTH drill pipe with API 2-3/8 REG box × pin connection, quoted by length, wall, bore and rig/hammer interface.

Especifique la interfaz completa de la sarta de perforación (no solo el diámetro exterior) para controlar el ajuste, el flujo de aire y la vida útil de la unión.

  • 76 mm de diámetro exterior
  • Conexión de caja × espiga API 2-3/8 REG
  • Longitud y dimensiones de sección confirmadas por el plano

Select

Request a Configuration-Based Quote

Send outside diameter and requested length, current thread evidence, rig or saver interface, hammer top-sub, operating context, quantity, destination, inspection and packing needs.

Technical Review Scope

Configuration and Quotation Guidance

Consulta sobre la configuración de tubería de perforación DTH de 76 mm. Esta página registra una referencia de conexión API 2-3/8 REG y referencias de longitud de 1.000, 1.500, 2.000 y 3.000 mm. Dichas referencias no definen por sí mismas una configuración completa de sarta de perforación.

Aviso de compatibilidad: una tubería descrita como API 2-3/8 REG no debe tratarse como un acople directo para un sub superior descrito como T48×10. La denominación CIR90 y el diámetro exterior de la tubería de 76 mm no garantizan la compatibilidad. Una coincidencia solo puede establecerse cuando un plano controlado de la misma rosca, un sub superior alternativo o un crossover identifica ambas interfaces y su revisión se incluye en la cotización.

Identidad de la configuración

PFM-DTH76-238-1000, PFM-DTH76-238-1500, PFM-DTH76-238-2000 y PFM-DTH76-238-3000 son referencias de consulta de longitud, no SKU completas para realizar pedidos. No determinan el espesor de pared, el diámetro interior, la geometría de la unión, el material, el peso, las condiciones de operación ni la revisión del plano.

Datos del comprador

  • Diámetro exterior de la tubería y longitud solicitada.
  • Referencia actual de la rosca y fotos o planos de ambos extremos roscados y hombros.
  • Interfaz del cabezal rotativo o sub de protección de la perforadora e interfaz del sub superior del martillo.
  • Requerimientos de pozo y profundidad, requerimientos de compresor o aire, torque de la perforadora, fuerza de retracción y condiciones de operación.
  • Cantidad, destino y cualquier requisito de inspección o embalaje.

Resultados de ingeniería y cotización

Antes de la aprobación técnica, el plano de cotización debe devolver el espesor de pared, el diámetro interior, la geometría de la unión, el apriete y la longitud total, los planos para llave, los detalles de rosca y hombro, la base de material y tratamiento térmico, la masa, las condiciones de operación permitidas y la revisión del plano. Un comprador puede indicar «no estoy seguro»; los resultados de ingeniería no deben ser adivinados por el comprador.

Límite de construcción

La construcción de la unión, el material del cuerpo de la tubería, la base del tratamiento térmico y el proceso de soldadura son elementos controlados de la cotización y el plano; no están definidos por esta página de consulta.

Límite de inspección y registros

Cualquier inspección de soldadura o método de END (ensayos no destructivos), alcance de muestra o lote, criterios de aceptación y requisitos de informe deben ser expresamente aceptados en la cotización o en la orden de compra; ninguno está incluido por defecto.

At a Glance

76 mmOutside Diameter
API 2-3/8 REG box × pinThread Connection
1.0 / 1.5 / 2.0 / 3.0 mListed Lengths

Technical Specifications

Outside Diameter76 mm
Thread ConnectionAPI 2-3/8 REG box × pin
Listed Lengths1.0 / 1.5 / 2.0 / 3.0 m
Wall, Bore and Joint DimensionsDrawing-controlled

Final interface dimensions, selected configuration and supply scope are stated in the formal quotation or approved drawing.

Compatibility and Required Interfaces

Rotary head or saver sub

API 2-3/8 REG

Mating API 2-3/8 REG connection and shoulder

Confirm box/pin orientation across the complete string.

DTH hammer top sub

API 2-3/8 REG

Mating thread, shoulder and airflow path

Provide hammer make/model or top-sub drawing.

DTH Drill-Pipe Configuration

Threaded Torque and Airflow Path

The box × pin joints transmit rotary torque while the internal bore carries compressed air to the DTH hammer.

Buyer value

A correctly matched connection and bore support joint life, airflow and stable make-up across the drill string.

Selection condition

Confirm thread gauge, shoulder dimensions, wall, bore, make-up practice and mating components.

Application Scenarios

  • Perforación DTH
  • Barrenos de voladura para canteras y minería
  • Perforación de pozos de agua y cimientos

Quality and Pre-Shipment Checks

01

Thread, Dimension and Visual Check

Recorded before shipment when included in the quotation

Approved length, OD, connection and ordered inspection scope

Verify specified dimensions, connection condition, markings and visible surface condition against the approved order.

Supply Scope, MOQ and Delivery

Minimum Order QuantityConfirmado en presupuesto por escrito
Lead TimeConfirmado en presupuesto por escrito

Available Supply Configurations

  • Lista de empaque final confirmada en el presupuesto por escrito

Export Packing

El embalaje final, la protección contra la corrosión, el método de cajón o palé y las marcas de envío se confirman en la cotización por escrito.

Warranty and After-Sales

La garantía, el alcance de los repuestos y las condiciones del servicio se confirman en la cotización escrita para la configuración del proveedor seleccionada.

Safety and Maintenance Notes

Utilícelo solo después de confirmar el modelo exacto, la interfaz, la presión de funcionamiento, la manguera, la lubricación y el manual suministrado. Siga las normativas locales, la evaluación de riesgos del lugar y el EPP requerido.

Guías técnicas y de selección

Utilice estas guías para confirmar la compatibilidad, los parámetros de funcionamiento, los puntos de inspección y los detalles de la solicitud de presupuesto antes de realizar el pedido.

Compatibilidad de roscas de tubería de perforación DTH: Guía de tamaños API REG

Selección del diámetro de la tubería de perforación DTH: Coincidencia del diámetro exterior de la tubería con el tamaño del orificio, el martillo y el flujo de aire

Selección de la longitud de la tubería de perforación DTH: Cómo elegir 1 m, 1,5 m, 2 m o 3 m

Cuidado de la rosca de la tubería de perforación DTH: Limpieza, lubricación, ajuste y prevención de grietas

Inspección previa al envío de la tubería de perforación DTH: Lista de verificación de roscas, rectitud, soldadura y embalaje

Order Documentation

Factura comercial y lista de empaque; cualquier certificado adicional se confirmará según el pedido

Frequently Asked Questions

Is 76 mm outside diameter enough to confirm compatibility?
No. Also confirm API 2-3/8 REG box/pin orientation, joint and shoulder dimensions, wall, bore, length, rotary-head or saver-sub connection, and hammer top sub.
Can you quote a length outside 1–3 m?
Yes, as a drawing-controlled configuration. Provide the required finished length, rig/hammer interface, handling limits, quantity and delivery country.

Matched Hammer and Rotary Interfaces

A complete 76 mm DTH string combines the rotary head or saver sub, API 2-3/8 REG drill pipe, matched hammer top sub and bit.

Ready to Confirm the Configuration?

Request a Quote for 76 mm / API 2-3/8 REG

Engineering will return the pipe geometry, interfaces, material and operating basis, controlled drawing revision and approved configuration ID. The approved identity must carry through quotation, purchase order, packing list and repeat order.

  • Product-specific quotation
  • Interface confirmation
  • Export packing options